Pair Identification
Pair 1 Blue/White w/Co-extruded Blue Strip on White Single
Pair 2 Orange/White w/Co-extruded Orange Strip on White Single
Pair 3 Green/White w/Co-extruded Green Strip on White Single
Pair 4 Brown/White w/Co-extruded Brown Strip on White Single
Characteristics
Installation Temperature:0℃to 60℃
Operation Temperature: -20℃to 60℃
Capacitance: 20pf/ft nominal
DC Resistance/Unbalance: 28.6 ohms/1000’Max/5% Max
Dielectric Breakdown: 2500 Volts DC Conductor to Conductor
Attenuation: ≤2.320•νfred + 0.238•fred 0.772≤fred≤16
Maximum Skew:11ns@100 meters
Structural Return Loss: ≥12 1≤fred≤10
≥12 – 10 log(fred/0.772) 10≤fred≤16
Electric Performance
Frequency |
Attenuation(dB/100m) |
Near End Cross Talk (dB) |
Structural Return |
MHz |
EIA/TIA 568 |
EIA/TIA 568 |
Loss (dB) |
|
Category 3 |
Category 3 |
|
0.772 |
6.8 |
43 |
NA |
1 |
7.8 |
41 |
12 |
4 |
17 |
32 |
12 |
8 |
25.9 |
27 |
12 |
10 |
30 |
26 |
12 |
16 |
40 |
23 |
10 |
Jacket Color: Gray, White, Blue, Orange, Purple, Green, Red, Yellow, Black etc.